Proline Prowirl R 200 vortex flowmeter

Category:

Description

    • Vortex

    • Product headline

      Flowmeter with best-in-class accuracy despite pipe reduction.
      Easy energy management – integrated temperature and pressure measurement for steam and gases.
      Dedicated to applications with very low flow or reduced flow.

    • Sensor features

      Cost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10″).

    • Transmitter features

      Cost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
      Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10″). Flexible positioning of pressure cell.

    • Nominal diameter range

      DN 25 to 250 (1 to 10″)

    • Wetted materials

      Measuring tube: 1.4408 (CF3M)
      DSC sensor: 1.4404/F316/F316L
      Process connection: 1.4404/F316/F316L

    • Measured variables

      Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

    • Max. measurement error

      Volume flow (liquid): ±0.75 %
      Volume flow (steam, gas): ±1.00 %
      Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
      Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
      Mass flow (liquid): ±0.85%

    • Measuring range

      Liquid: 0.2 to 540 m³/h (0.15 to 320 ft³/min)
      depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
      Steam, gas: 1.5 to 7260 m³/h (0.9 to 4270 ft³/min)
      depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

    • Max. process pressure

      PN 40, Class 300, 20K

    • Medium temperature range

      Standard: –40 to +260 °C (–40 to +500 °F)
      High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
      High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)

    • Ambient temperature range

      Compact version (standard): –40 to +80 °C (–40 to +176 °F)
      Compact version (option): –50 to +80 °C (–58 to +176 °F)
      Remote version (standard): –40 to +85 °C (–40 to +185 °F)
      Remote version (option): –50 to +85 °C (–58 to +185 °F)

    • Sensor housing material

      Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

    • Transmitter housing material

      AlSi10Mg, coated; 1.4404 (316L)

    • Degree of protection

      Compact version: IP66/67, type 4X enclosure
      Sensor remote version: IP66/67, type 4X enclosure
      Transmitter remote version: IP66/67, type 4X enclosure

    • Display/Operation

      4‐line backlit display with touch control (operation from outside)
      Configuration via local display and operating tools possible
      Remote display available

    • Outputs

      4‐20 mA HART (passive)
      4‐20 mA (passive)
      Pulse/frequency/switch output (passive)

    • Inputs

      4‐20 mA (passive)

    • Digital communication

      HART, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET over Ethernet-APL, Modbus TCP over Ethernet-APL

    • Power supply

      DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
      DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
      DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
      DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

    • Hazardous area approvals

      ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC

    • Product safety

      CE, C-tick, EAC

    • Functional safety

      Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

    • Metrological approvals and certificates

      Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
      Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    • Marine approvals and certificates

      ABS, LR, BV, DNV, CCS

    • Pressure approvals and certificates

      PED, CRN, AD 2000

    • Material certificates

      3.1 material
      NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)

Reviews

There are no reviews yet.

Be the first to review “Proline Prowirl R 200 vortex flowmeter”

Your email address will not be published. Required fields are marked *

Cart (0 items)
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare